Architects Information - Gerard Roofing Technologies

ARCHITECTS

Architects Specifications

CAD Drawings & Downloads

Specifications

GERARD TILE

Dimensions

Panel Width: 15.5” (393.7 mm) (39.37 cm)

Panel Length: 45.75” (1162.05 mm) (116.205 cm)

Pcs/ Square: 22.6

Weight/ Sq. Ft: 1.32 lbs (0.599 kg)

Weight/ per panel 5.83 lbs (2.64 kg)

 

Packaging

Each pallet contains 340 tiles (15 squares of material)

Pallet weight is 2,150 lbs (975 kg)

 

Installation

Open Rafter

Solid Sheathing

Batten mounted 2x2 wood or metal battens

Can re-roof over existing asphalt shingles*

Can re-roof over existing wood shake shingles*

Minimum Roof Slope: 2.5 : 12

Maximum Roof Slope: 12 : 12 or full vertical face

 

Substrate

26 gauge Galvalume®

 

Testings

UL- 790 Fire

UL-1897 Uplift

UL-580 Wind Uplift

UL-2218 Impact

 

Warranty

Transferable Limited Lifetime Warranty

 

Reports

City of LA Report

ICC ESR

Miami Dade County, FL NOA

Texas Department of Insurance

 

Extra

May reduce insurance premiums

May qualify for energy savings, rebates and or credits

 

* Check with local building code requirements


CANYON SHAKE

Dimensions

Panel Width: 16.5” (419.1 mm) (41.91 cm)

Panel Length: 45” (1143 mm) (114.3 cm)

Pcs/ Square: 22.6

Weight/ Sq.Ft: 1.32 lbs (0.599 kg)

Weight/ per panel: 5.83 lbs (2.64 kg)

 

Packaging

Each pallet contains 340 tiles (15 squares of material)

Pallet weight is 2,150 lbs (975 kg)

 

Installation

Open Rafter

Solid Sheathing

Batten mounted 2x2 wood or metal battens

Can be installed direct to deck (battenless)

Can re-roof over existing asphalt shingles*

Can re-roof over existing wood shake shingles*

Minimum Roof Slope: 3 : 12

Maximum Roof Slope: 12 : 12 or full vertical face

 

Substrate

26 gauge Galvalume®

 

Testings

UL- 790 Fire

UL-580 Wind Uplift

UL-2218 Impact

 

Warranty

Transferable Limited Lifetime Warranty

 

Reports

City of LA Report

ICC ESR

Miami Dade County, FL NOA

Texas Department of Insurance

 

Extra

May reduce insurance premiums

May qualify for energy savings, rebates and or credits

 

* Check with local building code requirements


NB TILE

Dimensions

Panel Width: 17.25” (438.15 mm) (43.815 cm)

Panel Length: 46” (1168.4 mm) (116.84 cm)

Pcs/ Square: 22.6

Weight/ Sq.Ft: 1.5 lbs (0.680 kg)

 

Installation

Open Rafter

Solid Sheathing

Battenless installation method

Can be batten mounted 2x2 wood or metal battens

Can re-roof over existing asphalt shingles*

Can re-roof over existing wood shake shingles*

Minimum Roof Slope: 2.5 : 12

Maximum Roof Slope: 12 : 12 or full vertical face

 

Substrate

26 gauge Galvalume®

 

Testings

UL- 790 Fire

UL-580 Wind Uplift

UL-2218 Impact

 

Warranty

Transferable Limited Lifetime Warranty

 

Reports

ICC ESR

Miami Dade County, FL NOA

Texas Department of Insurance

 

Extra

May reduce insurance premiums

May qualify for energy savings, rebates and or credits

 

* Check with local building code requirements


GRANITE RIDGE

Dimensions

Panel Width: 15.6” (396.26 mm) (39.62 cm)

Panel Length: 46.2” (1173.48 mm) (117.348 cm)

Pcs/ Square: 24

Weight/ Sq.Ft: 1.2 lbs (0.544 kg)

 

Installation

Solid Sheathing

Battenless installation method only

Can re-roof over existing asphalt shingles*

Can re-roof over existing wood shake shingles*

Minimum Roof Slope: 4 : 12

Maximum Roof Slope: 12 : 12 or full vertical face

 

Substrate

26 gauge Zinc Allum

 

Testings

UL- 790 Fire

UL-1897 Uplift

UL-580 Wind Uplift

UL-2218 Impact

 

Warranty

Transferable Limited Lifetime Warranty

 

Reports

ICC ESR

Miami Dade County, FL NOA

Texas Department of Insurance

 

Extra

May reduce insurance premiums

May qualify for energy savings, rebates and or credits

 

* Check with local building code requirements


GUARDIAN SHINGLE

Dimensions

Panel Width: 15.6” (396.24 mm) (39.62 cm)

Panel Length: 46.2” (1173.48 mm) (117.348 cm)

Pcs/ Square: 24

Weight/ Sq.Ft: 1.2 lbs (0.544 kg)

 

Installation

Solid Sheathing

Battenless installation method only

Can re-roof over existing asphalt shingles*

Can re-roof over existing wood shake shingles*

Minimum Roof Slope: 4 : 12

Maximum Roof Slope: 12 : 12 or full vertical face

 

Substrate

26 gauge Zinc Allum

 

Testings

UL- 790 Fire

UL-1897 Uplift

UL-580 Wind Uplift

UL-2218 Impact

 

Warranty

Transferable Limited Lifetime Warranty

 

Reports

Texas Department of Insurance

 

Extra

May reduce insurance premiums

May qualify for energy savings, rebates and or credits

 

* Check with local building code requirements


BARREL VAULT 

Dimensions

Panel Width: 16.25” (412.75 mm) (41.275 cm)

Panel Length: 45.5” (1155.7 mm) (115.57 cm)

Pcs/ Square: 24

Weight/ Sq.Ft: 1.5 lbs (0.680 kg)

 

Installation

Solid Sheathing

Open rafter

Battenless installation

Batten installation on 2x2 wood or metal battens

Can re-roof over existing asphalt shingles*

Can re-roof over existing wood shake shingles*

Minimum Roof Slope: 2:5 : 12

Maximum Roof Slope: 12 : 12 or full vertical face

 

Substrate

26 gauge Galvalume®

 

Testings

UL- 790 Fire

UL-1897 Uplift

UL-580 Wind Uplift

UL-2218 Impact

 

Warranty

Transferable Limited Lifetime Warranty

 

Reports

Texas Department of Insurance

ICC ESR

Miami Dade County, FL NOA

 

Extra

May reduce insurance premiums

May qualify for energy savings, rebates and or credits

 

* Check with local building code requirements


MISSION TRIM & SHAKE CAPS

For ridge, Rake and Hip areas  

Dimensions

Size is 15.5” x 6” (393.7 x 152.4 mm) (39.37 x 15.24 cm)

 

Packaging

1 pallet contains 16 boxes (800 pcs)

Weight per pallet is 1,045 lbs (474 kg)

Pallet size 42”x 54” (1066.8 x 1371.6 mm) (106.68 x 137.16 cm)

Each trim box contains 50 pcs of trim, 3 end discs and 1 touch up kit

menu.gif
Gerard Roofing Technologies - Stone Coated Steel Roofs

WARRANTY | LOCATIONS | TECHNICAL / CONTRACTORS | ARCHITECTS | REQUEST LITERATURE | SITE MAP

© 2006 Metals USA Building Products, L.P. d/b/a Gerard Roofing Technologies All rights reserved  LEGAL/PRIVACY

Financing Options by